Aluminum, Air plasma / air shield 45 a cutting, Metric english – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 127: Marking
OPERATION
HPR260 Auto Gas
Instruction Manual
4-33
Aluminum
Air Plasma / Air Shield
45 A Cutting
220202
220173
220308
220176
220180
220201
5
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
mm
Volts
mm
mm/m
mm
factor %
seconds
Air
Air
35
19
62
49
1.2
130
2.5
4750
3.8
150
0.2
1.5
115
4160
2
113
3865
2.5
110
3675
3
107
2850
33
4
102
1.8
2660
2.7
0.3
6
117
3.0
1695
4.5
0.6
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
in
Volts
in
ipm
in
factor %
seconds
Air
Air
35
19
62
49
.040
130
0.100
220
0.150
150
0.2
.051
115
170
.064
113
160
.102
110
140
33
.125
102
0.070
110
0.110
0.3
3/16
114
0.120
90
0.180
0.4
1/4
117
60
0.6
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps
mm
in
mm/min
ipm
Volts
N
2
N
2
10
10
10
10
15
2.5
0.100
6350
250
85
Marking
Flow rates – lpm/scfh
Air
Preflow
45 / 95
Cutflow
78 / 165