Stainless steel, Plasma / n, Shield 200 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 122: Metric english, Marking
OPERATION
4-28
HPR260 Auto Gas
Instruction Manual
4
Stainless steel
N
2
Plasma / N
2
Shield
200 A Cutting
220345
220398
220307
220344
220342
220343
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
mm
Volts
mm
mm/m
mm
factor %
seconds
N
2
N
2
20
42
84
42
10
160
3.8
2700
7.6
200
0.5
12
161
2400
0.6
15
163
1800
0.8
20
167
1000
1.0
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
in
Volts
in
ipm
in
factor %
seconds
N
2
N
2
20
42
84
42
3/8
160
0.150
110
0.300
200
0.5
1/2
161
90
0.6
5/8
163
65
0.8
3/4
167
45
1.0
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps
mm
in
mm/min
ipm
Volts
N
2
N
2
10
10
10
10
18
2.5
0.100
6350
250
140
Marking
Flow rates – lpm/scfh
N
2
Preflow
111 / 235
Cutflow
137 / 290