Aluminum, Plasma / n, Shield 200 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 293: Marking, English, Metric
APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS
c-24
HPR260 Auto Gas
Instruction Manual
Aluminum
N
2
Plasma / N
2
Shield
200 A Cutting
Plasma Shield Plasma Shield Plasma Shield
mm
Volts
mm
factor %
seconds
10
158
0.4
12
158
0.5
15
166
0.6
20
165
0.8
Plasma Shield Plasma Shield Plasma Shield
in
Volts
in
factor %
seconds
3/8
158
0.4
1/2
158
0.5
5/8
166
0.6
3/4
165
0.8
Marking
Amperage
Amps
mm
in
mm/min ipm
N
2
N
2
10
10
10
10
18
2.5
0.100
6350
250
Marking
Speed
Volts
140
Select
Gases
Set
Preflow
Set
Cutflow
Torch-to-Work
Distance
0.350
140
120
80
50
in
ipm
N
2
N
2
22
53
73
53
0.250
200
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
9.0
140
3500
2350
1000
mm
mm/m
N
2
N
2
22
53
73
53
6.4
4750
Metric
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Arc
Voltage
Flow rates – lpm/scfh
N
2
Preflow
113 / 240
Cutflow
135 / 287
220345
220398
220307
220347
220342
220346