Power supply to selection console cables -20, Control cable -20, Power cable -20 – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 69: Power supply to selection console cables, Control cable 5 power cable 6
INSTALLATION
3-20
HPR260 Auto Gas
Instruction Manual
3
Power supply to selection console cables
Control cable
5
Power cable
6
Cable signal list – power supply to selection console
Power supply end
Selection console end
Pin #
Input/Output
Description
Pin #
Input/Output
Function
1
unused
1
6
unused
6
2
Input/Output
CANL
2
Input/Output
CAN serial communication
7
Input/Output
CANH
7
Input/Output
CAN serial communication
3
CAN Ground
3
CAN ground reference
9
unused
9
unused
8
unused
8
4
unused
4
5
unused
5
Cable signal list – power supply to selection console
Power supply end
Selection console end
Pin # I/O
Description
Pin # I/O
Function
1
120 VAC-Hot
1
2
120 VAC-Return
2
3
Ground
3
4
unused
4
5
unused
5
6
24 VAC-Hot
6
7
24 VAC-Return
7
Part no.
Length
Part no.
Length
123784*
3 m (10 ft)
123737
25 m (82 ft)
123839
4.5 m (15 ft)
123738
35 m (115 ft)
123691
7.5 m (25 ft)
123739
45 m (150 ft)
123840
10 m (35 ft)
123842
60 m (200 ft)
123711
15 m (50 ft)
123843
75 m (250 ft)
123841
20 m (65 ft)
Part no.
Length
Part no.
Length
123785*
3 m (10 ft)
123740
25 m (82 ft)
123846
4.5 m (15 ft)
123676
35 m (115 ft)
123674
7.5 m (25 ft)
123677
45 m (150 ft)
123847
10 m (35 ft)
123849
60 m (200 ft)
123675
15 m (50 ft)
123850
75 m (250 ft)
123848
20 m (65 ft)
*
Cable numbers 123784 and 123785 are for use with systems that have the selection console mounted on the power supply