OPERATION

4-16

HPR260 Auto Gas

Instruction Manual

Mild steel

O

2

Plasma / O

2

Shield

50 A Cutting

220555

220173

220552

220313

220553

220554

Note: Air must be connected to use this process. It is used as the preflow gas

5

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma Shield Plasma Shield Plasma Shield

in

Volts

in

ipm

in

factor %

seconds

O

2

O

2

70

30

81

14

.030

110

0.04

270

0.08

200

0.0

.036

210

.048

112

160

.060

114

0.05

125

0.10

.075

115

110

.105

118

80

0.1

.135

120

0.06

60

0.12

0.2

3/16

121

50

0.3

1/4

125

0.08

35

0.16

0.5

5/16

130

25

English

Select

Gases

Set

Preflow

Set

Cutflow

Amperage

Torch-to-Work

Distance

Marking

Speed

Arc

Voltage

Amps

mm

in

mm/min

ipm

Volts

N

2

N

2

10

10

10

10

15

2.5

0.100

6350

250

118

Marking

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma Shield Plasma Shield Plasma Shield

mm

Volts

mm

mm/m

mm

factor %

seconds

O

2

O

2

70

30

81

14

0.8

110

1.0

6500

2.0

200

0.0

1

111

5000

1.2

112

4150

1.5

114

1.3

3200

2.6

2

115

2700

2.5

117

2200

0.1

3

119

1.5

1800

3.0

0.2

4

121

1400

0.3

5

122

1200

0.4

6

126

2.0

950

4.0

0.5

7

128

780

8

130

630

Metric

Flow rates – lpm/scfh

O

2

Air

Preflow

0 / 0

43 / 90

Cutflow

25 / 52

0 / 0