Aluminum, H35 plasma / n, Shield 260 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 295: Marking, English, Metric
![background image](https://www.manualsdir.com/files/789725/content/doc295.png)
APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS
c-26
HPR260 Auto Gas
Instruction Manual
Aluminum
H35 Plasma / N
2
Shield
260 A Cutting
Flow rates – lpm/scfh
H35
N
2
Preflow
0 / 0
127 / 270
Cutflow
33 / 70
118 / 250
Plasma Shield Plasma Shield Plasma
Shield
mm
Volts
mm
factor %
seconds
6
170
11.0
100
0.2
10
170
10.0
100
0.4
12
162
0.5
15
163
0.6
20
166
0.6
25
174
11.0
150
0.8
32
175
38
176
44
183
50
190
Plasma Shield Plasma Shield Plasma
Shield
in
Volts
in
factor %
seconds
1/4
170
0.450
100
0.2
3/8
170
0.400
100
0.4
1/2
162
0.5
5/8
163
0.6
3/4
166
0.6
1
174
0.450
150
0.8
1-1/4
175
1-1/2
176
1-3/4
183
2
190
Marking
Amperage
Amps
mm
in
mm/min ipm
N
2
N
2
10
10
10
10
18
2.5
0.100
6350
250
Marking
Speed
Select
Gases
Set
Preflow
Set
Cutflow
Torch-to-Work
Distance
Volts
120
N/A
45
25
14
0.330
110
130
90
0.400
250
0.300
190
75
60
in
ipm
H35
N
2
12
60
76
69
0.450
280
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
N/A
1150
670
390
8.5
110
3720
2230
10.0
6120
7.6
5160
1930
1510
mm
mm/m
H35
N
2
12
60
76
69
11.0
7200
Metric
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Arc
Voltage
220407
220398
220307
220344
220405
220406