beautypg.com

Placement of the selection console -14, Placement of the selection console – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 63

background image

INSTALLATION

3-14

HPR260 Auto Gas

Instruction Manual

3

Placement of the selection console

• Mount the selection console near the cutting table. Allow room to remove the top and right side cover for

servicing. Preferred orientation is shown in the figure below. The maximum length of cables between the power
supply and selection console is 75 m (250 ft). The maximum length of cables and hoses between the selection
console and the metering console assembly is 20 m (65 ft).

C

Preferred selection

console orientation

Selection console grounding

314.5 mm

12.38"

254.0 mm

10.0"

0

38.1 mm

1.5"

0

76.2 mm

3.0"