Aluminum, H35 plasma / n, Shield 200 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 292: Marking, English, Metric

APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS
HPR260 Auto Gas
Instruction Manual
c-23
Aluminum
H35 Plasma / N
2
Shield
200 A Cutting
Flow rates – lpm/scfh
H35
N
2
Preflow
0 / 0
113 / 240
Cutflow
34 / 72
90 / 190
Plasma Shield Plasma Shield Plasma Shield
mm
Volts
mm
factor %
seconds
10
152
0.3
12
150
0.4
15
150
0.5
20
159
0.6
Plasma Shield Plasma Shield Plasma Shield
in
Volts
in
factor %
seconds
3/8
152
0.3
1/2
150
0.4
5/8
150
0.5
3/4
159
0.6
Marking
Amperage
Amps
mm
in
mm/min ipm
N
2
N
2
10
10
10
10
18
2.5
0.100
6350
250
Marking
Speed
Select
Gases
Set
Preflow
Set
Cutflow
Torch-to-Work
Distance
Volts
140
0.350
140
140
110
70
in
ipm
H35
N
2
22
53
73
53
0.250
180
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
9.0
140
3800
3000
1450
mm
mm/m
H35
N
2
22
53
73
53
6.4
4400
Metric
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Arc
Voltage
220345
220398
220307
220347
220342
220346