Stainless steel, H35 plasma / n, Shield 260 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 124: Metric english, Marking
OPERATION
4-30
HPR260 Auto Gas
Instruction Manual
4
Stainless steel
H35 Plasma / N
2
Shield
260 A Cutting
220407
220398
220307
220344
220405
220406
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps
mm
in
mm/min
ipm
Volts
N
2
N
2
10
10
10
10
18
2.5
0.100
6350
250
120
Marking
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
mm
Volts
mm
mm/m
mm
factor %
seconds
H35
N
2
12
49
85
60
10
188
11.0
1870
11.0
100
0.3
12
173
9.0
1710
9.0
0.4
15
171
7.5
1465
120
0.5
20
175
1085
0.6
25
180
785
0.7
32
185
630
1.0
38
186
510
Edge start
44
189
390
50
200
270
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
in
Volts
in
ipm
in
factor %
seconds
H35
N
2
12
49
85
60
3/8
188
0.450
75
0.500
100
0.3
1/2
173
0.350
65
0.350
0.4
5/8
171
0.300
55
0.360
120
0.5
3/4
175
45
0.6
1
180
30
0.7
1-1/4
185
25
1.0
1-1/2
186
20
Edge start
1-3/4
189
15
2
200
10
Flow rates – lpm/scfh
H35
N
2
Preflow
0 / 0
127 / 270
Cutflow
40 / 84
122 / 260