Stainless steel, H35 plasma / n, Shield 260 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 285: Marking, English, Metric
APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS
c-16
HPR260 Auto Gas
Instruction Manual
Stainless steel
H35 Plasma / N
2
Shield
260 A Cutting
Flow rates – lpm/scfh
H35
N
2
Preflow
0 / 0
127 / 270
Cutflow
40 / 84
122 / 260
Plasma Shield Plasma Shield Plasma Shield
mm
Volts
mm
factor %
seconds
10
188
11.0
0.3
12
173
0.4
15
171
0.5
20
175
0.6
25
180
0.7
32
185
1.0
38
186
44
189
50
200
Plasma Shield Plasma Shield Plasma Shield
in
Volts
in
factor %
seconds
3/8
188
0.500
0.3
1/2
173
0.350
0.4
5/8
171
0.5
3/4
175
0.6
1
180
0.7
1-1/4
185
1.0
1-1/2
186
1-3/4
189
2
200
Marking
Amperage
Amps
mm
in
mm/min ipm
N
2
N
2
10
10
10
10
18
2.5
0.100
6350
250
75
100
0.360
English
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Select
Gases
Set
Preflow
100
120
390
270
Metric
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
mm
mm/m
H35
N
2
12
59
85
71
11.0
1870
9.0
1710
9.0
7.5
1465
1085
785
630
510
N/A
Set
Cutflow
Material
Thickness
Pierce Delay
Time
in
ipm
H35
N
2
12
59
85
71
0.450
0.350
65
0.300
55
20
120
45
30
25
N/A
15
10
Select
Gases
Set
Preflow
Set
Cutflow
Torch-to-Work
Distance
Marking
Speed
Volts
120
Arc
Voltage
220407
220398
220307
220344
220405
220406