Error codes – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 265
APPENDIX B – CNC INTERFACE PROTOCOL
b-20
HPR260 Auto Gas
Instruction Manual
5
Error codes
ID
Name
Description
000
NO ERROR
System is ready to run.
012
TEST IN PROGRESS
One of the gas test modes is running.
013
TEST PASSED
The test completed successfully.
014
CUT GAS CHANNEL #1 FAIL
The gas pressure is dropping on channel #1, indicating a leak.
015
CUT GAS CHANNEL #2 FAIL
The gas pressure is dropping on channel #2, indicating a leak.
016
PLASMA RAMP-DOWN FAIL
Pump output has exceeded 200 psi.
017
SHIELD RAMP-DOWN FAIL
Shield pressure did not decrease in the allotted time.
018
PUMP OVER PRESSURE
Pump output has exceeded 13.79 bar (200 psi.)
020
NO PILOT ARC
No current detected from chopper at ignition and before 1-second
timeout.
021
NO ARC TRANSFER
No transfer signal detected before 500-msec timeout.
024
LOST CURRENT
After transfer, lost the chopper current signal.
026
LOST TRANSFER
After transfer, lost the transfer signal.
027
LOST PHASE
When main contactor is engaged, no “phase OK” input.
030
GAS SYSTEM ERROR
A failure has occurred in the gas system.
031
START LOST
Start signal was removed before steady-state operation.
032
HOLD TIMEOUT
Hold signal was applied for longer than 60 seconds.
033
PRE CHARGE TIMEOUT
Gas console was not able to charge the gas lines to the correct
pressure.
042
LOW NITROGEN PRESSURE
Nitrogen gas pressure under lower limit of 2.07 bar (30 psi) –
cutting, 0.34 bar (5 psi) – marking
044
LOW PLASMA GAS PRESSURE
Gas pressure under lower limit of 0.34 bar (5 psi) – pre-flow
3.45 bar (50 psi) – cutflow (cutting) 0.34 bar (5 psi) – cutflow
(marking).
045
HIGH PLASMA GAS PRESSURE
Gas pressure over upper limit of 7.58 bar (110 psi).
046
LOW LINE VOLTAGE
Line voltage is under lower limit of 102 VAC (120 VAC -15%).
047
HIGH LINE VOLTAGE
Line voltage is over upper limit of 138 VAC (120 VAC +15%).
048
CAN ERROR
An error occurred with the CAN communication system.
050
START ON AT INIT
Start signal input is active during power-up.
053
LOW SHIELD GAS PRESSURE
Gas pressure is under lower limit of 0.14 bar (2 psi).
054
HIGH SHIELD GAS PRESSURE
Gas pressure is over upper limit of 7.58 bar (110 psi).
055
MV 1 INLET PRESSURE
Motor valve 1 inlet pressure is less than 3.45 bar (50 psi) or
greater than 9.65 bar (140 psi).
056
MV 2 INLET PRESSURE
Motor valve 2 inlet pressure is less than 3.45 bar (50 psi) or
greater than 9.65 bar (140 psi).
057
CUT GAS 1 PRESSURE
In the selection console, cut gas 1 outlet pressure is less than
3.45 bar (50 psi) or greater than 9.65 bar (140 psi).
058
CUT GAS 2 PRESSURE
In the selection console, if cut gas 2 outlet pressure is less than
3.45 bar (50 psi) for non-mixing, or less than 1.38 bar (20 psi)
when mixing or greater than 9.65 bar (140 psi) for non-mixing and
mixing.
060
LOW COOLANT FLOW
Coolant flow is less than the required 2.3 lpm (0.6 gpm).
061
NO PLASMA GAS TYPE
Plasma gas has not been selected.
062
NO SHIELD GAS TYPE
Shield gas has not been selected, or system is in test mode.
065
CHOPPER1 OVERTEMP
Chopper #1 overheated.
066
CHOPPER2 OVERTEMP
Chopper #2 overheated.
067
MAGNETICS OVERTEMP
Transformer has overheated.
071
COOLANT OVERTEMP
Torch coolant has overheated.