INSTALLATION

HPR260 Auto Gas

Instruction Manual

3-37

Connect the power

1. Insert the power cable through the strain relief at the rear of the power supply.

2. Connect the ground lead (PE) to the GROUND terminal of TB1 as shown below.

3. Connect the power leads to the terminals of TB1 as shown below.

4. Check that the line disconnect switch is in the OFF position and remains in the OFF position for the

remainder of the installation of the system.

5. Connect the power cord leads to the line disconnect switch following national or local electrical codes.

North American wire colors
U = Black
V = White
W = Red
(PE) Earth ground = Green/Yellow

DANGER

E

LECTRICAL SHOCK CAN KILL

T

he line disconnect switch must be in the OFF position before making the power cable connections.

In the U.S., use a “lock-out/tag-out” procedure until installation is complete. In other countries,
follow appropriate national or local safety procedures.

Line

disconnect

switch

Power

cable

TB1

W

V

GND

U

European wire colors
U = Black
V = Blue
W = Brown
(PE) Earth ground = Green/Yellow