Aluminum, H35 and n, Plasma / n – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 294: Shield 200 a cutting, Marking, English, Metric
APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS
HPR260 Auto Gas
Instruction Manual
c-25
Aluminum
H35 and N
2
Plasma / N
2
Shield
200 A Cutting
Flow rates – lpm/scfh
H35
N
2
Preflow
0 / 0
121 / 256
Cutflow
13 / 27
126 / 267
Plasma Shield Plasma Shield Plasma Shield
Mix
Gas 1
Mix
Gas 2
mm
Volts
mm factor %
seconds
10
158
0.3
12
158
0.4
15
162
0.5
20
170
0.6
Plasma Shield Plasma Shield Plasma Shield
Mix
Gas 1
Mix
Gas 2
in
Volts
in
factor %
seconds
3/8
158
0.3
1/2
158
0.4
5/8
162
0.5
3/4
170
0.6
Marking
mm
in
mm/min
N
2
N
2
10
10
10
10
2.5
0.100
6350
18
250
140
Torch-to-Work
Distance
Amps
ipm
Volts
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
0.250
160
0.350
140
140
80
50
in
ipm
H35
N
2
22
53
73
53
42
20
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-
Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce
Delay Time
6.4
4000
9.0
140
3650
2450
1050
mm
mm/m
H35
N
2
22
53
73
53
42
20
Metric
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-
Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce
Delay Time
Marking
Speed
Arc
Voltage
220345
220398
220307
220347
220342
220346