Mild steel, Plasma / air shield 80 a cutting, Marking – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 272: Metric, English
APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS
HPR260 Auto Gas
Instruction Manual
c-3
Mild steel
O
2
Plasma / Air Shield
80 A Cutting
220189
220173
220187
220176
220179
220188
Flow rates – lpm/scfh
O
2
Air
Preflow
0 / 0
76 / 161
Cutflow
23 / 48
41 / 87
Plasma Shield Plasma Shield Plasma Shield
mm
Volts
mm
factor %
seconds
2
112
2.5
115
3
117
4
120
6
123
0.3
10
127
0.5
12
130
0.7
15
133
0.8
20
135
6.3
0.9
Plasma Shield Plasma Shield Plasma Shield
in
Volts
in
factor %
seconds
.075
112
.105
115
.135
117
3/16
120
1/4
123
0.3
3/8
127
0.5
1/2
130
0.7
5/8
133
0.8
3/4
135
0.250
0.9
Marking
Amperage
Amps
mm
in
mm/min ipm
N
2
N
2
10
10
10
10
15
2.5
0.100
6350
250
250
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
0.200
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
0.160
0.100
in
ipm
400
0.150
Pierce Delay
Time
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Initial Pierce
Height
0.2
200
110
75
250
5.0
545
3045
1810
1410
O
2
Air
48
27
15
2.5
2.0
78
23
2.5
0.2
0.1
3.8
150
200
4.0
Pierce Delay
Time
Metric
37
25
15
0.100
0.080
155
50
78
English
0.1
23
O
2
Air
48
27
150
290
180
Select
Gases
Marking
Speed
Torch-to-Work
Distance
mm
mm/m
1030
9810
7980
6145
4300
Volts
130
Set
Cutflow
Set
Preflow
Arc
Voltage