beautypg.com

Aluminum, H35 plasma / n, Shield 130 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 290: Marking, English, Metric

background image

APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS

HPR260 Auto Gas

Instruction Manual

c-21

Aluminum

H35 Plasma / N

2

Shield

130 A Cutting

220198

220173

220307

220304

220179

220197

Note: This process produces a smoother cut edge with smaller average angles than the 130A, Air/Air process

Flow rates – lpm/scfh

H35

N

2

Preflow

0 / 0

76 / 160

Cutflow

26 / 54

68 / 144

Plasma Shield Plasma Shield Plasma Shield

mm

Volts

mm

factor %

seconds

54

10

158

6.5

130

0.3

42

12

156

0.5

15

156

0.8

20

157

1.3

20

25

176

Plasma Shield Plasma Shield Plasma Shield

in

Volts

in

factor %

seconds

54

3/8

158

0.260

130

0.3

42

1/2

156

0.5

5/8

156

0.8

3/4

157

1.3

20

1

176

Amperage

Amps

mm

in

mm/min ipm

N

2

N

2

10

10

10

10

18

2.5

0.100

6350

250

Marking

5.0

4.5

1615

1455

540

Initial Pierce

Height

0.180

0.310

170

Set

Preflow

Set

Cutflow

Material

Thickness

19

38

75

27

Pierce Delay

Time

English

H35

7.7

170

N/A

N

2

1305

940

Metric

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Select

Gases

N/A

55

50

40

20

27

H35

N

2

19

38

75

in

65

Torch-to-Work

Distance

Cutting

Speed

0.200

ipm

Initial Pierce

Height

Pierce Delay

Time

mm

mm/m

Volts

130

Select

Gases

Set

Preflow

Set

Cutflow

Torch-to-Work

Distance

Marking

Speed

Arc

Voltage