Mild steel, Marking, Metric – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 274: English, Plasma / air shield 200 a cutting
APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS
HPR260 Auto Gas
Instruction Manual
c-5
Plasma Shield Plasma Shield Plasma Shield
mm
Volts
mm
factor %
seconds
6
124
0.2
10
126
0.3
12
128
0.5
15
131
0.6
20
133
0.8
25
143
1.0
32
145
N/A
38
152
N/A
50
163
N/A
Plasma Shield Plasma Shield Plasma Shield
in
Volts
in
factor %
seconds
3/16
124
0.2
1/4
124
0.2
3/8
126
0.3
1/2
128
0.5
5/8
131
0.6
3/4
133
0.8
1
143
1.0
1-1/4
145
N/A
1-1/2
152
N/A
2
163
N/A
Marking
Amperage
Plasma Shield Plasma Shield Plasma Shield
Amps
mm
in
mm/min ipm
N
2
N
2
10
10
10
10
15
2.5
0.100
6350
250
Metric
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
mm
mm/m
O
2
Air
23
49
74
20
3.3
5250
6.6
200
3460
3060
4.1
2275
8.2
1575
5.1
1165
10.2
750
510
255
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
in
ipm
O2
Air
23
49
74
20
0.130
230
0.260
200
200
140
115
0.160
80
0.320
65
0.200
45
0.400
30
20
10
Volts
130
Select
Gases
Set
Preflow
Set
Cutflow
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Mild steel
O
2
Plasma / Air Shield
200 A Cutting
Flow rates – lpm/scfh
O
2
Air
Preflow
0 / 0
128 / 270
Cutflow
39 / 82
48 / 101
220356
220398
220352
220355
220353
220354