Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 266

APPENDIX B – CNC INTERFACE PROTOCOL
HPR260 Auto Gas
Instruction Manual
b-21
5
ID
Name
Description
072
AUTOMATIC GAS CONTROL BOARD
OVERTEMP
Control board has exceeded 90° C (194° F).
093
NO COOLANT FLOW
Coolant flow is less than 0.6 gpm.
099
CHOPPER1 OVERTEMP AT INIT
Chopper #1 is indicating overtemp during power-up.
100
CHOPPER2 OVERTEMP AT INIT
Chopper #2 is indicating overtemp during power-up.
101
MAGNETICS OVERTEMP AT INIT
Transformer is indicating overtemp during power-up.
102
OUTPUT CURRRENT AT INIT
Chopper current signal is active on power-up.
103
CURRENT TOO HIGH ON LEM #1
A current greater than 35 amps has been detected by current
sensor 1.
104
CURRENT TOO HIGH ON LEM #2
A current greater than 35 amps has been detected by current
sensor 2.
105
CURRENT TOO LOW ON LEM #1
A current less than 10 amps has been detected by current
sensor 1.
106
CURRENT TOO LOW ON LEM #2
A current less than 10 amps has been detected by current
sensor 2.
108
TRANSFER AT INIT
The system has detected current on the work lead during
power-up.
109
COOLANT FLOW AT INIT
Coolant flow is greater than 1.14 lpm (0.3 gpm) when pump is
off.
111
COOLANT OVERTEMP AT INIT
Coolant is indicating overtemp during power-up.
116
WATCHDOG INTERLOCK
CAN communication error.
123
MV 1 ERROR
Motor valve 1 did not move into position within 60 seconds.
124
MV 2 ERROR
Motor valve 2 did not move into position within 60 seconds.
133
UNKNOWN GAS CONSOLE TYPE
The power supply control board does not recognize the gas
console installed or has not received a CAN message identifying
the type of console installed.
134
CHOPPER 1 OVERCURRENT
Chopper 1 current feedback has exceeded 160 amps.
138
CHOPPER 2 OVERCURRENT
Chopper 2 current feedback has exceeded 160 amps.
139
PURGE TIMEOUT ERROR
The purge cycle did not complete within 3 minutes.
140
AUTO GAS PRESSURE TRANSDUCER
#1 ERROR
Faulty transducer or auto gas control PCB
141
AUTO GAS PRESSURE TRANSDUCER
#2 ERROR
Faulty transducer or auto gas control PCB
142
AUTO GAS PRESSURE TRANSDUCER
#3 ERROR
Faulty transducer or auto gas control PCB
143
AUTO GAS PRESSURE TRANSDUCER
#4 ERROR
Faulty transducer or auto gas control PCB
144
MANUAL GAS CONSOLE INTERNAL
FLASH MEMORY ERROR
Replace manual gas console control PCB
145
AUTOMATIC GAS CONSOLE INTERNAL
FLASH MEMORY ERROR
Replace auto gas console control PCB
151
SOFTWARE FAIL
Software has detected an incorrect state or condition.
152
INTERNAL FLASH ERROR
DSP memory is not working properly.
153
PS EEPROM ERROR
EEPROM memory on power supply board not working.
180
SELECTION CONSOLE CAN TIMEOUT
Power supply has not received a CAN message from the
selection console within 1 second
181
METERING CONSOLE CAN TIMEOUT
Power supply has not received a CAN message from the
metering console within 1 second