Stainless steel, F5 plasma / n, Shield 80 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 117: Metric english, Marking
![background image](https://www.manualsdir.com/files/789725/content/doc117.png)
OPERATION
HPR260 Auto Gas
Instruction Manual
4-23
Stainless steel
F5 Plasma / N
2
Shield
80 A Cutting
220338
220173
220339
220304
220179
220337
4
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
mm
Volts
mm
mm/m
mm
factor %
seconds
F5
N
2
33
23
65
37
4
108
3.0
2180
4.5
150
0.2
6
112
2.5
1225
3.8
0.3
10
120
3.0
560
4.5
0.5
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
in
Volts
in
ipm
in
factor %
seconds
F5
N
2
33
23
65
37
.135
108
0.120
105
0.180
150
0.2
3/16
110
0.110
60
0.170
0.3
1/4
112
0.100
45
0.150
3/8
120
0.120
25
0.180
0.5
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps
mm
in
mm/min
ipm
Volts
N
2
N
2
10
10
10
10
15
2.5
0.100
6350
250
95
Marking
Flow rates – lpm/scfh
F5
N
2
Preflow
0 / 0
67 / 142
Cutflow
31 / 65
55 / 116