beautypg.com

Command table (3 of 13) – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 253

background image

APPENDIX B – CNC INTERFACE PROTOCOL

b-8

HPR260 Auto Gas

Instruction Manual

Command table (3 of 13)

ID

Command

System

Description

068

SYSTEM_RESET

Manual gas system
Auto gas system

Clear error conditions and resume operation. Only accepted
if system is in a shutdown error condition (Error code > 79
and State = 14).

Data:
None

Return value:
1 = accepted, 0 = not accepted

Sample:
>0689E<
>0681CF<

070

SET_CORNER_CURRENT

Manual gas system
Auto gas system

When CORNER CURRENT input is activated the power
supply will switch to the current percentage specified.

Data:
% of cutting current (50-100%)
50=50%

Return value:
% achieved

Sample:
>0707503<
>070007563< (set 75%)<

071

MANUAL_PUMP_CONTROL

Manual gas system
Auto gas system

Used to override software control of the coolant pump. If the
system has a fatal error, the pump cannot be overridden.

Data:
1 = override software to force pump on, 0 = system software
controls the pump, override off

Return value:
1 = accepted, 0 = not accepted

Sample:
>0711C9<
>0711C9<

072

GET_CONTROL_VOLTAGE

Manual gas system
Auto gas system

Returns the internal control voltage of the power supply

Data:
None

Return value:
Voltage (1/10 V)
1200 = 120.0 V

Sample:
>07299<
>07212005C< (120.0 volts)

5