Command table (3 of 13) – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 253
APPENDIX B – CNC INTERFACE PROTOCOL
b-8
HPR260 Auto Gas
Instruction Manual
Command table (3 of 13)
ID
Command
System
Description
068
SYSTEM_RESET
Manual gas system
Auto gas system
Clear error conditions and resume operation. Only accepted
if system is in a shutdown error condition (Error code > 79
and State = 14).
Data:
None
Return value:
1 = accepted, 0 = not accepted
Sample:
>0689E<
>0681CF<
070
SET_CORNER_CURRENT
Manual gas system
Auto gas system
When CORNER CURRENT input is activated the power
supply will switch to the current percentage specified.
Data:
% of cutting current (50-100%)
50=50%
Return value:
% achieved
Sample:
>0707503<
>070007563< (set 75%)<
071
MANUAL_PUMP_CONTROL
Manual gas system
Auto gas system
Used to override software control of the coolant pump. If the
system has a fatal error, the pump cannot be overridden.
Data:
1 = override software to force pump on, 0 = system software
controls the pump, override off
Return value:
1 = accepted, 0 = not accepted
Sample:
>0711C9<
>0711C9<
072
GET_CONTROL_VOLTAGE
Manual gas system
Auto gas system
Returns the internal control voltage of the power supply
Data:
None
Return value:
Voltage (1/10 V)
1200 = 120.0 V
Sample:
>07299<
>07212005C< (120.0 volts)
5