Remote on/off switch -28, Remote on/off switch (provided by customer), Danger – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 77
INSTALLATION
3-28
HPR260 Auto Gas
Instruction Manual
1. Locate terminal block 2 (TB2) in the power supply.
2. Remove wire 1 and wire 3 as shown. These wires do not need to be reconnected.
3. Connect switch to terminals 1 and 3 as shown.
TB2 location
1
2
3
1
3
TB2
1
3
1
2
3
TB2
1
3
Note: Use a switch, relay or solid-state relay that is compatible with 24 VAC @ 100 mA. It must be a
maintained contact switch, not a momentary contact switch.
Remote ON/OFF switch (provided by customer)
5
DANGER
ELECTRIC SHOCK CAN KILL
Disconnect electrical power before performing any maintenance.
See the Safety section in this manual for more safety precautions.
This manual is related to the following products: