Aluminum, H35 plasma / n, Shield 200 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 131: Metric english, Marking
OPERATION
HPR260 Auto Gas
Instruction Manual
4-37
4
Aluminum
H35 Plasma / N
2
Shield
200 A Cutting
220345
220398
220307
220347
220342
220346
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
mm
Volts
mm
mm/m
mm
factor %
seconds
H35
N
2
22
43
73
43
10
152
6.4
4400
9.0
140
0.3
12
150
3800
0.4
15
3000
0.5
20
159
1450
0.6
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
in
Volts
in
ipm
in
factor %
seconds
H35
N
2
22
43
73
43
3/8
152
0.250
180
0.350
140
0.3
1/2
150
140
0.4
5/8
110
0.5
3/4
159
70
0.6
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps
mm
in
mm/min
ipm
Volts
N
2
N
2
10
10
10
10
18
2.5
0.100
6350
250
140
Marking
Flow rates – lpm/scfh
H35
N
2
Preflow
0 / 0
113 / 240
Cutflow
34 / 72
90 / 190