beautypg.com

Error code troubleshooting – 9 of 10 -19 – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 163

background image

MAINTENANCE

HPR260 Auto Gas

Instruction Manual

5-19

Error code troubleshooting – 9 of 10

Error code

number

Name

Description

Corrective action

138

Chopper 2

overcurrent

(HPR260

power

supplies)

Chopper 2 current
feedback has exceeded
160 amps.

1. Verify that the wiring between CS2 and PCB3 is correct

and not damaged.

2. Measure voltage across current sensor.

a) Red to black = +15 VDC, Green to black = -15 VDC,

white to black = 0 VDC at idle and varies with current
output (4 VDC = 100 amps).

b) If possible, take a voltage reading on current sensor

while trying to cut. Ratio is 4 VDC = 100 amps.

c) If the current sensor voltage is approximately 6.4 VDC or

greater at idle, replace the current sensor.

3. Remove connector J9.1 from the chopper and verify that

LED1 is extinguished.
a) If LED1 is extinguished with the connector removed,

then reconnect J9.1 and try to fire the torch. If the
chopper still goes into overcurrent, replace the chopper.

b) If the chopper does not go into overcurrent, replace

PCB3.

139

Purge

time-out error

The purge cycle did not
complete within 3 minutes.

This is a warning for a possible gas restriction in the leads.
Verify that there are no restrictions in the plasma and shield
hoses.

140

Pressure

transducer
1or 8 error

Auto Gas

Only

Faulty transducer or
control board in the
metering console or the
selection console.

1. Verify that transducer P1 in the selection console is

working properly. Replace if necessary.

2. Verify that transducer P8 in the metering console is working

properly. Replace if necessary.

3. Verify that the control boards in the metering and selection

consoles are working properly. Replace if necessary.

141

Pressure

transducer

2 or 7 error

Auto Gas

Only

Faulty transducer or
control board in the
metering console or the
selection console.

1. Verify that transducer P2 in the selection console is

working properly. Replace if necessary.

2. Verify that transducer P7 in the metering console is working

properly. Replace if necessary.

3. Verify that the control boards in the metering and selection

consoles are working properly. Replace if necessary.

142

Pressure

transducer

3 or 5 error

Auto Gas

Only

Faulty transducer or
control board in the
metering console or the
selection console.

1. Verify that transducer P3 in the selection console is

working properly. Replace if necessary.

2. Verify that transducer P5 in the metering console is working

properly. Replace if necessary.

3. Verify that the control boards in the metering and selection

consoles are working properly. Replace if necessary.

143

Pressure

transducer

4 or 6 error

Auto Gas

Only

Faulty transducer or
control board in the
metering console or the
selection console.

1. Verify that transducer P4 in the selection console is

working properly. Replace if necessary.

2. Verify that transducer P6 in the metering console is working

properly. Replace if necessary.

3. Verify that the control boards in the metering and selection

consoles are working properly. Replace if necessary.

5