Aluminum, Plasma / n, Shield 200 a cutting – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual
Page 132: Metric english, Marking

OPERATION
4-38
HPR260 Auto Gas
Instruction Manual
4
Aluminum
N
2
Plasma / N
2
Shield
200 A Cutting
220345
220398
220307
220347
220342
220346
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
mm
Volts
mm
mm/m
mm
factor %
seconds
N
2
N
2
22
43
73
43
10
158
6.4
4750
9.0
140
0.4
12
3500
0.5
15
166
2350
0.6
20
165
1000
0.8
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
in
Volts
in
ipm
in
factor %
seconds
N
2
N
2
22
43
73
43
3/8
158
0.250
200
0.350
140
0.4
1/2
120
0.5
5/8
166
80
0.6
3/4
165
50
0.8
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps
mm
in
mm/min
ipm
Volts
N
2
N
2
10
10
10
10
18
2.5
0.100
6350
250
140
Marking
Flow rates – lpm/scfh
N
2
Preflow
113 / 240
Cutflow
135 / 287