APPENDIX B – CNC INTERFACE PROTOCOL
b-6
HPR260 Auto Gas
Instruction Manual
Command table (1 of 13)
ID
Command
System
Description
000
HELLO
Manual gas system
Auto gas system
Establish communications with the plasma system. Use this command
to identify which system you are talking to.
Data:
None
Return value:
String identifying the system
Sample:
>00090<
>000HYPERFORMANCE130MANUALB5<
or
>000HYPERFORMANCE130AUTO30<
or
>000HYPERFORMANCE130AUTOMIX1E<
001
VERSION
Manual gas system
Auto gas system
Get the version of the power supply firmware
Data:
None
Return value:
Power supply firmware then Gas console firmware, space-delimited
Sample:
>00191<
>001A.0 A.25<
(power suppy rev A, gas rev A)
002
GET_STATE
Manual gas system
Auto gas system
Get the current state of the plasma system.
Data:
None
Return value:
Status code (see table V)
Sample:
>00292<
>002000052< (status code 0)
003
LAST_ERROR
Manual gas system
Auto gas system
Get the last error that occurred at the system.
Data:
None
Return value:
Error code (see table IV)
Sample:
>00393<
>00301165B< (error code 116)
004
REMOTE_MODE
Manual gas system
Auto gas system
Switch system into remote mode, to allow remote control of the plasma
system.
Data:
None
Return value:
1 = accepted, 0 = not accepted
Sample:
>00494<
>0041C5<