beautypg.com

Examples of output circuits – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 75

background image

INSTALLATION

3-26

HPR260 Auto Gas

Instruction Manual

Examples of output circuits

1. Logic interface, active-high

2. Logic interface, active-low

3. Relay interface

4. Do not use this configuration. Warranty will be void.

High-impedance (≤10mA)

10K
(optional)

CNC/PLC

5 VDC-24 VDC

C

HPR

E

+

-

HPR

C

E

+

-

5 VDC-24 VDC

High-impedance (≤10mA)

CNC/PLC

10K
(optional)

CNC/PLC

CNC +24 V

+24 VDC

CNC +24 V

HPR

C

E

+

-

Power

ground

External relay
24 VDC low-power coil
≤10 mA or ≥2400 ohm

High-current
contact closure
inputs (AC or DC)

°t

Any voltage

VO

IDS

WA

RRANTY

HPR

Install a

Jumper

108056

J304

C

E

+

-