background image

Installation and Setup

26

Redundant Control - IMG 1010

Topic Location: IMG 1010-Installation and Setup Guide > IMG 1010-Hardware

Installation

The following illustration shows the cabling for redundant control for Network Management.

1.

The Ctrl 0 and Ctrl1 ports are used for communication between the Linux Server

(GCEMS) and the IMG 1010.

The CTRL0 and CTRL1 Ports will use the same IP address.

The CTRL1 MAC addresses is CTRL0 MAC + 1.

The MAC address of CTRL0 and CTRL1 are configured through BootP using the

DHCP service on the GCEMS Linux server or using the SD Card. See

dhcpd.conf

The CTRL ports are used for communication to the GCEMS server for

configuration and monitoring. These ports can also be used for the following:

SIP / H.323 signaling

NFS for download routing, translation tables, and call treatments

SNTP

SNMP