beautypg.com

2 rf converter module, 3 reference oscillator module, 4 lna curent fault – Comtech EF Data CSAT-5060 User Manual

Page 75

background image

C-Band Transceiver

Revision 1

Maintenance and Troubleshooting MN/CSAT5060.IOM

7–3

7.3.2

RF Converter Module

Synthesizer and IFLO Lock Detect Fault:

During normal operation, neither the Upconverter nor the Downconverter synthesizer or
IFLO should experience a Lock Detect fault.

• If one or more of these functions is faulted the CSAT will not function properly.
• If a fault condition exists and an EXT REF is being used, check the connection to

the CSAT and make sure it is secure.

• It may be necessary to remove the EXT REF if it is faulty.

If the fault still exists, contact Comtech EF Data Customer Support.

7.3.3

Reference Oscillator Module

Reference

Lock

Detect:

A fault ("FT") indicates that the reference oscillator is not locked. Check all connections
to the converter module to make sure they are secure. If the fault still exists, contact
Comtech EF Data Customer Support.

7.3.4

LNA Curent Fault

LNA Curent Fault:

This can indicate either a problem in the CSAT LNA current source circuitry or a
problem with the LNA.

• First, ensure that the LNA is connected and that no shorts exist. Use the RMS?

Command to query the measured LNA current.

• If the LNA and cable are OK, proceed to disconnect the LNA and measure from

the center conductor of the cable to the shield of the cable using a DVM. A
voltage of 12Vdc shall be measured if the LNA Current Source is Enable (i.e.,
LCS=1).

Contact Comtech EF Data Customer Support for further troubleshooting.