CSAT-5060 C-Band Transceivers

Revision 1

Appendix A

MN/CSAT5060.IOM

A–21

CSAT Remote Commands
Parameter

Type

Command

Arguments

Description of arguments

Response to

Command

Query

Response to

Query

Concise Alarm

Status

N/A

19 bytes,

numerical

Query only.

Used to Query the Alarm status of the CSAT

Example: CMS=abcdefghijklmnopqr’cr’’lf’

where: a thru n = 0 or 1, 0 = OK 1 = FT

a = 24V Power Supply Alarm

b = 20V Power Supply Alarm

c = 12V Power Supply Alarm

d = 10V Power Supply Alarm

e = +5V Power Supply Alarm

f = -5V Power Supply Alarm

g = TX Synthesizer Lock Detect Alarm

h = TX IFLO Lock Detect Alarm

I = RX Synthesizer Lock Detect Alarm

j = RX IFLO Lock Detect Alarm

k = Reference Lock Detect Alarm

l = LNA Current Alarm

m = Fan Current Alarm

n = Temperature Alarm

o = HPA Thermal Shutdown Alarm

p = Internal IIC-bus Alarm

q = EEPROM checksum Alarm

r = NVRAM/RTC Low Battery Alarm

s = Redundancy switch alarm

N/A

CAS?

CAS=x….x

See Note 2

Summary Fault

Status

N/A

1 byte,

alpha numerical

Query only.

Used to Query the status of the CSAT Summary

Fault Relay.

Example: SFS=0’cr’’lf’

where: 0 = OK 1 = FT

N/A

SFS?

SFS=x

See Note 2

Retrieve Firmware

Number for the

M&C board

N/A

6 bytes,

alpha numerical

Query only.

Used to Query M&C board’s firmware number

Example: FRW=FW1516

N/A

FRW?

FRW=x

See Note 2