beautypg.com

Comtech EF Data CSAT-5060 User Manual

Page 207

background image

CSAT-5060 C-Band Transceivers

Revision 1

Appendix A

MN/CSAT5060.IOM

A–11

CSAT Remote Commands
Parameter

Type

Command

Arguments

Description of arguments

Response to

Command

Query

Response to

Query

TX Slope Adjust

USA=

3 bytes

Command or Query.

TX Slope Adjust, between 0.0 and 1.0.

Resolution = 0.1.

Example: USA=0.3

USA= (message ok)

USA? (received ok, but

invalid arg. found)

USA?

USA=x.x

See Note 1

RX Slope Mode

DSM=

1 byte,

value of 0,1

Command or Query.

RX Slope Mode, where:

0 =Manual Mode,

1 = Calibrated Mode.

Example: DSM=1

DSM=(message ok)

DSM?(received ok, But

invalid argument found)

DSM? DSM=x

See Note 1

RX Slope Adjust

DSA=

3 bytes

Command or Query.

RX Slope Adjust, between 0.0 and 1.0.

Resolution = 0.1.

Example: DSA=0.3

DSA= (message ok)

DSA? (received ok, but

invalid arg. found)

DSA?

DSA=x.x

See Note 1

Reference

Oscillator Adjust

REF=

3 bytes

Command or Query.

Ref Osc Adjust, between 000 and 255.

Resolution 001.

Example: REF=087

Note: REF cannot be adjusted when the CSAT

is locked to an external reference source.

REF= (message ok)

REF? (received ok, but

invalid argument found)

REF* (message ok, but

not permitted in current

mode)

REF?

REF=xxx

See Note 1

Cold Start

CLD=

1 byte,

value of 0,1

Command or Query.

Cold Start, where:

0 = Disabled,

1 = Enabled

Example: CLD=1

CLD= (message ok)

CLD? (received ok, but

invalid arguments

found)

CLD?

CLD=x

See Note 1

Auto Fault

Recovery

AFR=

1 byte,

value of 0,1

Command or Query.

Auto Fault Recovery, where:

0 = Disabled,

1 = Enabled

Example: AFR=1

AFR= (message ok)

AFR? (received ok, but

invalid arguments

found)

AFR?

AFR=x

See Note 1

Online Status

N/A

1 byte,

value of 0,1

Query Only.

Online status, where:

0 = OFFLINE,

1 = ONLINE

Example: ONL=1

ONL= (message ok)

ONL? (received ok, but

invalid arguments

found)

ONL?

ONL=x

See Note 1