beautypg.com

Comtech EF Data CSAT-5060 User Manual

Page 70

background image

C-Band Transceiver

Revision 1

Remote Control

MN/CSAT5060.IOM


6-18

Parameter
Type

Command
(Instruction
Code and
qualifier)

Arguments
for
Command
or
Response
to Query

Description of arguments

Note that all arguments are ASCII
numeric codes between 48 and 57.

Response to
Command

(Slave to Master)

Query

(Instruction
code and
qualifier)

Response to query

(Slave to Master)

Concise
Configuration
Status

N/A

31 bytes,
alpha
numerical

Query only.

Used to Query the Configuration status of the CSAT

Example: CCS=uuuu.udddd.daa.aabb.bbotamrncfx’cr’’lf’

where:

uuuu.u = TX frequency

dddd.d = RX frequency

aa.aa = TX attenuation

bb.bb = RX attenuation

o = online status, 0 = OFFLINE, 1 = ONLINE

t = transmitter status, 0 = OFF, 1 = ON

a = amplifier status, 0 = OFF, 1 = ON

m = TX mute status, 0 = Unmuted, 1 = Muted

r = receiver status, 0 = OFF, 1 = ON

n = RX mute status, 0 = Unmuted, 1 = Muted

c = cold start, 0 = Disabled, 1 = Enabled

f = auto fault recover, 0 = Disabled, 1 = Enabled

x = external reference present, 0 = NO, 1 = YES

N/A CCS?

CCS=x….x (see description for
details of arguments)

Concise LNA
Status

N/A

4 bytes,
alpha
numerical

Query only.

Used to Query the LNA status of the CSAT

Example: CLS=abbc’cr’’lf’

where:

a = LNA Current 0=OFF, 1=ON

bb = Current window in %

c = LNA Fault Logic 0=OFF, 1=ON

N/A CLS?

CLS=x….x (see description for
details of arguments)