Mute Mode

MUT=

1 byte,
value of 0,1

Command or Query.

Mute Mode, where:

0 = Unmuted after Frequency change,

1 = Muted after Frequency change.

Example: MUT=1

MUT=(message ok)

MUT?(received ok,
but invalid argument
found)

MUT? MUT=x

(same format as command
argument)

TX Mute

UMU=

1 byte,
value of 0,1

Command or Query.

TX Mute, where:

0 = Transmitter Unmuted,

1 = Transmitter Muted

Example: UMU=1

UMU=(message ok)

UMU?(received ok,
but invalid argument
found)

UMU? UMU=x

(same format as command
argument)

RX Mute

DMU=

1 byte,
value of 0,1

Command or Query.

RX Mute, where:

0 = Receiver Unmuted,

1 = Receiver Muted

Example: DMU=1

DMU=(message ok)

DMU?(received ok,
but invalid argument
found)

DMU? DMU=x

(same format as command
argument)

TX Slope
Mode

USM=

1 byte,
value of 0,1

Command or Query.

TX Slope Mode, where:

0 =Manual Mode,

1 = Calibrated Mode.

Example: USM=1

USM=(message ok)

USM?(received ok,
But invalid argument
found)

USM? USM=x

(same format as command
argument)

TX Slope
Adjust

USA=

3 bytes

Command or Query.

TX Slope Adjust, between 0.0 and 1.0.

Resolution = 0.1.

Example: USA=0.3

USA= (message ok)

USA? (received ok,
but invalid arg.
found)

USA? USA=x.x

(same format as command
argument)

RX Slope
Mode

DSM=

1 byte,
value of 0,1

Command or Query.

RX Slope Mode, where:

0 =Manual Mode,

1 = Calibrated Mode.

Example: DSM=1

DSM=(message ok)

DSM?(received ok,
But invalid argument
found)

DSM? DSM=x