beautypg.com

Aa.5.2 user login – Comtech EF Data CSAT-5060 User Manual

Page 172

background image

CSAT-5060 C-Band Transceiver

Revision 1

Ethernet-based Remote Product Management

MN/CSAT5060.IOM

AA–8

4.

Use the LRS remote command to set the Ethernet remote control access parameter:

Use default remote command LRS=3 for Serial + Ethernet control.

Use remote command LRS=2 for Ethernet control only.

5.

If necessary, use the IPA remote command to set a unique IP address.

Each unit must have a unique IP address assigned before connection to a

network.

If the IP address needs to be changed from the factory default setting, use the

IPA=xxx.xxx.xxx.xxx.yy remote command, where ‘xxx.xxx.xxx.xxx’ is a valid IP address on

the network where the unit will be installed, and ‘yy’ is the range (typically, yy=24).

If you change the IPA value, make sure to shut off and restart the unit; then, start a new

Telnet session using the new IP address.

AA.5.2

User Login

Do these steps to log in to the Web Server Interface. A a compatible web browser is required.

1.

On the PC, type http://192.168.1.4 (the default IP address for the unit) into the

browser’s Address area, and then press Enter.