beautypg.com

Comtech EF Data CSAT-5060 User Manual

Page 219

background image

CSAT-5060 C-Band Transceivers

Revision 1

Appendix A

MN/CSAT5060.IOM

A–23

CSAT with Ethernet Remote Commands

Parameter

Type

Command

Arguments

Description of arguments

Response to Command

Query

Response to

query

Unit MAC Address

N/A

17 bytes

Query Only

MAC address of the unit, reported in hexadecimal.

Example: MAC=00-06-B0-00-D2-A7

N/A

MAC?

MAC=xx-xx-xx-xx-

xx-xx

See Note 2

Time Protocol

Enable

TPE=

1 byte

Command or Query.

Current Active software image, where:

0 = Time protocol disabled

1 = Time protocol enabled

Example: TPE=1 (Time protocol enabled)

TPE=

TPE?

TPE?

TPE=x

See Note 2

Time Protocol

Server

TPS=

15 bytes

Used to set the Time Server IP address for the

Unit. Tx Ethernet management port, in the format:

xxx.xxx.xxx.xxx, where:

xxx.xxx.xxx.xxx is the Time server IP address

Example: IPG = 192.168.001.005

TPS=

TPS?

TPS?

TPS=

xx.xxx.xxx.xxx.yy

See Note 2

Local/

Remote

Status

LRS=

1 bytes

Command or Query.

Used set the user’s Local/Remote status in the form x,

where:

1=Serial Remote (RS-232/RS-485)

2=Ethernet

3=Ethernet and Serial

4=FSK

Example: LRS=1 (selects Serial Remote)

Note: Changing LRS to FSK mode may cause some

serial remote commands reply with # code (hardware

resource issues).

LRS=

LRS?

LRS?

LRS=x

See Note 2

Part Number

N/A

variable length

1 – 95 bytes

Query only

Returns the Comtech EF Data part number of the unit.

This

part number is the unit’s DOTCODE at the time it was

manufactured. The DOTCODE may be up to 95 printable

ASCII characters long.

Example: <1/PNM?’cr’

>0001/PNM=CSAT5060-005’cr’’lf’

N/A

PNM?

PNM=x[1..95]

See Note 2