beautypg.com

Comtech EF Data CSAT-5060 User Manual

Page 210

background image

CSAT-5060 C-Band Transceivers

Revision 1

Appendix A

MN/CSAT5060.IOM

A–14

CSAT Remote Commands
Parameter

Type

Command

Arguments

Description of arguments

Response to

Command

Query

Response to

Query

Redundancy

Controller Box

Toggle

RTG=

None

Command only.

RTG= sent to the online CSAT will cause the Redundancy

Box to toggle the TX and RX switches.

Example: RTG=

RTG= (message ok)

RTG? (received ok, but

invalid arguments

found)

N/A

N/A

Remote Address

(Physical Address)

SPA=

4 bytes,

numerical

Command or Query.

Physical Address - between 0001 and 9999.

Resolution 0001.

Example: SPA=0890

SPA= (message ok)

SPA? (received ok, but

invalid arguments found)

SPA?

SPA=xxxx

See Note 1

Remote Baud rate

SBR=

4 bytes

Command or Query.

Baud Rate, as follows:

1200 = 1200 baud,

2400 = 2400 baud,

4800 = 4800 baud,

9600 = 9600 baud,

19K2 = 19200 baud.

38K4 = 38400 baud.

Note: Unit responds on the existing baud rate and then

changes to the new baud rate.

SBR= (message ok)

SBR? (received ok, but

invalid arguments found)

SBR?

SBR=xxxx

See Note 1

Set RTC Date

DAY=

6 bytes,

numerical

A command in the form mmddyy, where; dd = day of the

month, between 01 and 31, mm = month of the year,

between 01 and 12 and yy = year, between 97 and 96

(1997 to 2000, then 2000 to 2096)

Example: DAY=042457 would be April 24, 2057

DAY= (message ok)

DAY? (received ok, but

invalid arguments found)

DAY* (message ok, but

not permitted in current

mode

DAY?

DAY=xxxxxx

See Note 1

Set RTC Time

TIM=

6 bytes,

numerical

A command in the form hhmmss, indicating the time from

midnight, where hh = hours, between 00 and 23; mm =

minutes, between 00 and 59, and ss = seconds, between

00 and 59

Example: TIM=231259 would be 23 hours, 12 minutes and

59 seconds from midnight.

TIM= (message ok)

TIM? (received ok, but

invalid arguments found)

TIM* (message ok, but

not permitted in current

mode

TIM?

TIM=xxxxxx

See Note 1

Clear All Stored

Alarms

CAA=

None

Command only

Instructs the slave to clear all Stored Events

This command takes no arguments.

CAA= (message ok)

N/A

N/A