C-Band Transceiver
Revision 1
Redundant Systems
MN/CSAT5060.IOM
5–5
5.1.1.7
Tx IF Interfaces, J6, J7, and J8
The Tx IF input signal is fed from the customer’s equipment to the RSU-5060 at
connector J6. The RSU-5060 contains a power splitter which feeds the IF input signal to
both CSAT A and CSAT B via the J7 and J8 connectors. The IF power at J7 and J8 will
nominally be 3dBm less than the IF input power at J6.
5.1.1.8
Rx IF Interfaces, J9 – J11
The Rx IF output signal is fed to the customer’s equipment from the RSU-5060 at
connector J9. The RSU-5060 contains a power combiner which takes the IF input signals
from both CSAT A and CSAT B via the J10 and J11 connectors and provides a single
output signal at J9. The IF output power at J9 will nominally be 3dBm less than the IF
input power at either J10 or J11.
5.1.2
Mechanical Interface
The RSU-5060 is housed in a weather resistant, sealed aluminum housing with five
external circular connectors and six Female N-Type connectors. The mechanical
dimensions and mounting interface are shown in Chapter 2.