4.2.16

Redundancy Controller Auto/Manual

The Operating mode of the Comtech EF Data Redundant Switch Unit (RSU-
5060) can be set via a command to the ONLINE CSAT. The RSU-5060
initializes to the AUTO mode when power is first applied.

• In AUTO mode the RSU-5060 monitors the state of the two CSATs

and will automatically switch the OFFLINE unit online if the ONLINE
unit faults.


• In MANUAL mode, the RSU-5060 will only switch the position of the

Tx and Rx transfer switches when commanded to do so via either the
RTG= command or via Pin V on the ‘M&C Control’ connector (J5) on
the RSU-5060. The user sets AUTO mode by sending a ‘1’ in the data
field and MANUAL mode with a ‘0’ in the data field.

Associated Remote Command(s):

RAM=

Example(s): RAM=1

4.2.17

Redundancy Controller Toggle

The User can cause the RSU-5060 Redundant Switch Unit to switch the
position of both the Tx and Rx transfer switches using this command.

• If the RSU-5060 is in AUTO mode, the command will only cause a

switchover if the OFFLINE unit is currently UNFAULTED.


• If the RSU-5060 is in MANUAL mode, the command will cause a

switchover independent of the state of the OFFLINE unit.

Associated Remote Command(s):

RTG=

Example(s): RTG=

4.2.18 Set

Physical

Address

The Remote (Physical) address to which the CSAT will respond can be set to
any value between 0001 and 9999. (The factory default is 0001)

Associated Remote Command(s):

SPA=

Example(s): SPA=0001