AA.5.5.3.6 Config | LNA Page

Use this page to configure the Low Noise Amplifier (LNA) current alarm settings. At any time,

click Refresh to update this page and see the most recent data.

Figure AA-11. Config | LNA page

LNA Current Source

Use the drop-down list to select Enabled , Disabled or Offline LNA Disabled for the LNA Current

Source. Click Change to save the setting.

Current Window

Enter a percentage value from 20 to 50 in increments of 1 percent. If the monitored LNA Current

exceeds this value, an alarm occurs. If you set the value to 99, the LNA Current alarm monitoring

is disabled. Click Change to save the setting.

LNA Fault Logic

Use the drop-down list to select No Summary Fault or Summary Fault. Click Change to save the

setting.

Calibrate

Click Send the Command to set the calibration point for the LNA Current alarm.