beautypg.com

Comtech EF Data CSAT-5060 User Manual

Page 69

background image

C-Band Transceiver

Revision 1

Remote Control

MN/CSAT5060.IOM


6-17

Parameter
Type

Command
(Instruction
Code and
qualifier)

Arguments
for
Command
or
Response
to Query

Description of arguments

Note that all arguments are ASCII
numeric codes between 48 and 57.

Response to
Command

(Slave to Master)

Query

(Instruction
code and
qualifier)

Response to query

(Slave to Master)

Retrieve
Alarm Status

N/A

171 bytes,
text

Query only.

Used to Query the Alarm status of the CSAT

Example: RAS=’cr’

24VLT=OK’cr’

20VLT=OK’cr’

12VLT=OK’cr’

10VLT=OK’cr’

P5VLT=OK’cr’

N5VLT=OK’cr’

USYNH=OK’cr’

UIFLO=OK’cr’

DSYNH=OK’cr’

DIFLO=OK’cr’

REFLD=OK’cr’

LNACR=OK’cr’

FANMN=OK’cr’

HSTMP=OK’cr’

SHTDN=OK’cr’

IICFT=OK’cr’

CHKSM=OK’cr’

BATLW=OK’cr’

REDSW=OK’cr’’lf’

N/A RAS?

RAS=x….x (see description for
details of arguments)