CDM-700 High Speed Satellite Modem
Revision 5
Front Panel Operation
MN/CDM700.IOM
6–44
GBEI Statistics Summary
Category
Message
Description
Mng Undersize (In)
Removed, V1.3.1 and later
Mng Collisions (In)
The sum of collisions detected on the WAN
Mng Fragments (In)
Total frames received from the local GBEI management processor
with a length of less than 64 octets and an invalid FCS
Mng Oversize (In)
Total frames received form the local GBEI management processor
with a length greater than the maximum size of octets but with a valid
FCS
Mng Jabber (In)
Removed, V1.3.1 and later
Mng Discards (In)
The number of management processor packets that have been
discarded due to GBEI switch congestion
Mng Rx Err (In)
Total frames received from the local GBEI management processor
for which an error was detected by its physical interface
Mng FCS Err (In)
Total frames received from the local GBEI management processor
with a CRC error which was not counted in the Fragments or Rx Err
totals
Mng Octets (Out)
The sum of the lengths of all Ethernet frames transmitted to the local
GBEI management processor
Mng Unicast (Out)
The sum of frames transmitted to the local GBEI management
processor that have a unicast destination MAC address
Mng Broadcast (Out)
The sum of frames transmitted to the local GBEI management
processor that have a broadcast destination MAC address
Mng Multicast (Out)
The sum of frames transmitted to the local GBEI management
processor that have a multicast destination MAC address
Intfc1 Gigabit Ethernet:
Æ SWOP (Switch Operation)
Intfc1 SWOP:
AutoCx Learning Mode (efE)
This section describes the menu selections for setting up VLAN operation when SWOP (Switch
Operation) is selected from the (CONFIG:) Intfc1 Gigabit Ethernet: menu.
Select AutoCx, Learning, or Mode using the
◄ ►
arrow keys. Press
ENTER
.
If Intfc1 SWOP: Æ AutoCx is selected:
Intfc1 Auto Crossover:
Enable Disable (E)
If enabled, the Gigabit Ethernet Interface automatically detects the type of connection and
configures the interface appropriately as straight-through (MDI) or crossover (MDIX).
If disabled, the Gigabit Ethernet port is configured as straight-through (MDI).
Select Enable or Disable using the ◄ ► arrow keys. Press
ENTER
.