beautypg.com

Comtech EF Data CDM-700 User Manual

Page 162

background image

CDM-700 High Speed Satellite Modem

Revision 5

Remote Control

MN/CDM700.IOM

11–12

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Interface Rx
Data Rate

IRR=

1 bytes

Command or Query.
Interface Rx Data rate, in Mbps:

s=Defines which interface slot (1 or 2)
c=Defines which channel (1 to 2)
xxx.xxxxxx=Defines the transmit data rate in Mbps.

Resolution=1 bps.

*Note: Interface types G.703 and GbEI cannot vary in
datarate.

Example: IRR=11002.047999 (which is 2.047999 Mbps) on slot
1 channel 1.

IRR=
IRR?
IRR*
IRR#

IRR?sc

IRR= xxx.xxxxxx
(see description of
arguments)

Rx Frequency

RFQ=

9 bytes

Command or Query.
Rx Frequency:
- IF: 52-88 MHz and 104-176 MHz.
- L-Band: 950-1950 MHz.
Resolution=100 Hz

Example: RFQ=0140.9872

RFQ=
RFQ?
RFQ*
RFQ#

RFQ? RFQ=xxxx.xxxx

(see description of
arguments)