Front Panel Operation
MN/CDM700.IOM
6–9
If M&C Bus Interface Æ RS232 is selected:
In RS232 Mode the Bus
Address is fixed at 0000
If M&C Bus Interface Æ RS485-2W or RS485-4W is selected, further prompting occurs:
RS485 Bus Address: 0001
(E)
Edit the RS485 bus address of the modem by selecting the digit to be edited, using the ◄ ►
arrow keys. The value of the digit is then changed using the ▲ ▼ arrow keys. The valid range of
addresses is from 1 to 9999. Press
ENTER
.
If Serial Config: Æ Baudrate is selected:
Local M&C Bus Baud Rate:
9600 Baud ( E )
Edit the Baud rate of the remote control bus, connected locally to the M&C computer. Values of
1200, 2400, 4800, 9600, 19200, 38400, and 57600 baud are possible. The value is changed using
the ◄ ► arrow keys. Press
ENTER
.
Note: The Asynchronous character format is FIXED at 8 data bits, No parity, and 1 stop bit (8-N-
1).
Remote Control:
Æ Ethernet
Ethernet Config: Gateway
Address MAC SNMP ( E)
Select Gateway, Address, MAC, or SNMP using the ◄ ► arrow keys, then press
ENTER
.
If Ethernet Config: Æ Gateway is selected:
Ethernet IP Gateway:
063.168.001.127 ( E )
The IP Gateway address is the default address that the modem will send all IP responses when the
message originated from a source outside the modems local attached network.
Edit the IP Gateway address by selecting the digit to be edited, using the ◄ ► arrow keys. The
value of the digit is then changed using the ▲ ▼ arrow keys. Press
ENTER
.