Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Rx Spectrum
Invert

RSI=

1 byte

Command or Query.
Rx Spectrum Invert, where:
0=Normal
1=Rx Spectrum Invert

Example: RSI=0 (selects Normal)

RSI=
RSI?
RSI*
RSI#

RSI?

RSI=x
(see description of
arguments)

Rx
Descrambler

RDS=

1 byte

Command or Query.
Rx Descrambler state, where:
0=Off
1=On

Example: RDS=1 (Scrambler On)

RDS=
RDS?
RDS*
RDS#

RDS?

RDS=x
(see description of
arguments)

Rx Data Invert

RDI=

3 bytes

Command or Query.
Invert Receive Data, where:
s=Defines which interface slot ( 1 or 2 )
c=Defines which channel ( 1 to 2 )
x=Invert Receive Data, where:
0=Normal
1=Inverted

(Note: Command valid Only with CDI-10 Dual G.703 and CDI-60
HSSI interface. For HSSI the ‘c’ parameter is always ‘1’)

Example: RDI = 111 (selects Inverted RX Data)

RDI=
RDI?
RDI*
RDI#

RDI?sc

RDI=scx
(see description of
arguments)

Rx Clock
Invert

RCI=

2 bytes

Command or Query.
Invert Receive Clock, where:
s=Defines which interface slot ( 1 or 2 )
x=Invert Receive Clock, where:
0=Normal
1=Inverted

(Note: Command valid Only with CDI-60 HSSI interface)

Example: RCI = 11 (selects Inverted RX Clock, Slot 1)

RCI =
RCI?
RCI *
RCI #

RCI?s

RCI =sx
(see description of
arguments)

Rx Demod
Acquisition
Sweep Width

RSW=

3 bytes

Command or Query.
Rx

± acquisition sweep range of demodulator, in kHz, ranging

from

± 1 to ± 100 kHz.

Example: RSW=009 (selects

± 9 kHz)

RSW=
RSW?
RSW*
RSW#

RSW?

RSW=xxx
(see description of