Comtech EF Data CDM-700 User Manual
Page 164

CDM-700 High Speed Satellite Modem
Revision 5
Remote Control
MN/CDM700.IOM
11–14
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx Spectrum
Invert
RSI=
1 byte
Command or Query.
Rx Spectrum Invert, where:
0=Normal
1=Rx Spectrum Invert
Example: RSI=0 (selects Normal)
RSI=
RSI?
RSI*
RSI#
RSI?
RSI=x
(see description of
arguments)
Rx
Descrambler
RDS=
1 byte
Command or Query.
Rx Descrambler state, where:
0=Off
1=On
Example: RDS=1 (Scrambler On)
RDS=
RDS?
RDS*
RDS#
RDS?
RDS=x
(see description of
arguments)
Rx Data Invert
RDI=
3 bytes
Command or Query.
Invert Receive Data, where:
s=Defines which interface slot ( 1 or 2 )
c=Defines which channel ( 1 to 2 )
x=Invert Receive Data, where:
0=Normal
1=Inverted
(Note: Command valid Only with CDI-10 Dual G.703 and CDI-60
HSSI interface. For HSSI the ‘c’ parameter is always ‘1’)
Example: RDI = 111 (selects Inverted RX Data)
RDI=
RDI?
RDI*
RDI#
RDI?sc
RDI=scx
(see description of
arguments)
Rx Clock
Invert
RCI=
2 bytes
Command or Query.
Invert Receive Clock, where:
s=Defines which interface slot ( 1 or 2 )
x=Invert Receive Clock, where:
0=Normal
1=Inverted
(Note: Command valid Only with CDI-60 HSSI interface)
Example: RCI = 11 (selects Inverted RX Clock, Slot 1)
RCI =
RCI?
RCI *
RCI #
RCI?s
RCI =sx
(see description of
arguments)
Rx Demod
Acquisition
Sweep Width
RSW=
3 bytes
Command or Query.
Rx
± acquisition sweep range of demodulator, in kHz, ranging
from
± 1 to ± 100 kHz.
Example: RSW=009 (selects
± 9 kHz)
RSW=
RSW?
RSW*
RSW#
RSW?
RSW=xxx
(see description of
arguments)