CDM-700 High Speed Satellite Modem
Revision 5
Connector Pinouts
MN/CDM700.IOM
The pinout table for the P1 connector in Redundancy mode is as follows:
Alarm Connector Pinout P1 – Redundancy Mode
[ 1:1 (CRS-170A, CRS-180) and 1:N (CRS-300/700) ]
Pin #
Description
Name
Direction
8
Program Relay NC
PR-NC
I/O
15
Program Relay NO
PR-NO
I/O
7
Program Relay COM
PR-COM
I/O
14
Clock Detect
Clk Det
I
6
Aux Tx Enable
Red_Out_4
O
13 No
Connection
NC
NC
5
Fused –12 VDC Output (160 mA max)
-12VDC
O
12
Fused +12 VDC Output (160 mA max)
+12VDC
O
4 Online
Red_In_2
I
11 Serial
Clock Red_Out_1
O
3 Serial
Data Red_Out_2
O
10
Receive Serial Data – auxiliary channel
Red_In_3
I
2
Transmit Serial Data – auxiliary channel
Red_Out_3
O
9
Ext Carrier Off
Red_In_1
I
1 Ground
GND
Gnd
Note : For both the Normal Mode and the CRS-170A/180 and CRS300/700 and
Redundancy Modes of operation:
•
Prior to October 2007, the relays have low voltage contacts with transient
suppressors across each pin to ground. The maximum working voltage = 18VDC
or 13VAC. The maximum current rating is 1 Amp DC or 0.5 Amp AC. The
Summary Relay combines Tx, Rx, and Unit Faults into a single relay.
•
The suppressors were removed, as of October 2007, with Framer Card S/N
071539628. The Summary Relay combines Tx, Rx, and Unit Faults into a single
relay.