beautypg.com

Comtech EF Data CDM-700 User Manual

Page 52

background image

CDM-700 High Speed Satellite Modem

Revision 5

Connector Pinouts

MN/CDM700.IOM

The pinout table for the P1 connector in Redundancy mode is as follows:

Alarm Connector Pinout P1 – Redundancy Mode

[ 1:1 (CRS-170A, CRS-180) and 1:N (CRS-300/700) ]

Pin #

Description

Name

Direction

8

Program Relay NC

PR-NC

I/O

15

Program Relay NO

PR-NO

I/O

7

Program Relay COM

PR-COM

I/O

14

Clock Detect

Clk Det

I

6

Aux Tx Enable

Red_Out_4

O

13 No

Connection

NC

NC

5

Fused –12 VDC Output (160 mA max)

-12VDC

O

12

Fused +12 VDC Output (160 mA max)

+12VDC

O

4 Online

Red_In_2

I

11 Serial

Clock Red_Out_1

O

3 Serial

Data Red_Out_2

O

10

Receive Serial Data – auxiliary channel

Red_In_3

I

2

Transmit Serial Data – auxiliary channel

Red_Out_3

O

9

Ext Carrier Off

Red_In_1

I

1 Ground

GND

Gnd


Note : For both the Normal Mode and the CRS-170A/180 and CRS300/700 and
Redundancy Modes of operation:

Prior to October 2007, the relays have low voltage contacts with transient
suppressors across each pin to ground. The maximum working voltage = 18VDC
or 13VAC. The maximum current rating is 1 Amp DC or 0.5 Amp AC. The
Summary Relay combines Tx, Rx, and Unit Faults into a single relay.

The suppressors were removed, as of October 2007, with Framer Card S/N
071539628. The Summary Relay combines Tx, Rx, and Unit Faults into a single
relay.



5–6