CDM-700 High Speed Satellite Modem
Revision 5
Front Panel Operation
MN/CDM700.IOM
6–51
View Negotiation
If Negotiation Æ View is selected, the current negotiation is displayed. See the following
sample screens:
Intfc1 GBEI Negotiation
100 HDPX
Intfc1 GBEI Negotiation
100 FDPX
Intfc1 GBEI Negotiation
1000 FDPX
6.3.1.7.1 (CONFIG:) Intfc2 (CDI-70 Gigabit Ethernet Interface)
The CDM-700 can be configured with a second CDI-70 Gigabit Ethernet interface board plugged
into interface Slot2 (Intfc2). The menus are identical to what is presented in 6.3.1.7 (CONFIG:)
Intfc1 (CDI-70 Gigabit Ethernet Interface) except that Intfc2, rather than Intfc1, is displayed in
all menus.
6.3.1.8 (CONFIG:)
Ref
Frequency Reference
Internal 10 MHz ( E)
Select either Internal 10 MHz, or the External 1, 2, 5, 10, 20 MHz using the
▲ ▼
arrow keys.
The external reference is applied to J7 Ext Ref on the main chassis – not a data interface module.
6.3.1.9 (CONFIG:)
Aux
Redundancy Mode:
Ena/Dis Force(1:1) (efE)
Ena/Dis (Enable/Disable) is used to configure the modem for 1:1 or 1:N operation. The Force
(1:1) selection is only available for use with a 1:1 switch to force switchover.
Note: In VLAN Redundancy, OFFLINE Modem is VLAN UNAWARE.
Select Ena/Dis or Force (1:1) using the ◄ ► arrow keys. Press
ENTER.
If Redundancy Mode: Æ Ena/Dis is selected: