beautypg.com

Comtech EF Data CDM-700 User Manual

Page 48

background image

CDM-700 High Speed Satellite Modem

Revision 5

Connector Pinouts

MN/CDM700.IOM

Modem Rear Panel Connectors Table for Initially Released Chassis Version:

Name

Ref.

Des.

Connector Type

Function

Tx IF Output

J1

BNC Female

70/140 MHz IF Output

Type N Female

L-Band IF Output

Rx IF Input

J3

BNC Female

70/140 MHz IF Input

Type N Female

L-Band IF Input

10/100 Ethernet

J4

RJ-45 Female

Ethernet Management

SerDes

J6

RJ-45 Female

Private communications link

Ext Ref

J7

SMA Female

External reference input

Alarm

P1

15-pin ‘D’ Male

Alarm connector and Form C contacts

RS232/485

P2

9-pin ‘D’ Male

Remote Port

AC INPUT

NONE

IEC 320

Prime Power Input

GROUND NONE

10-32

Stud Grounding

Note: The initially-released chassis does not support 1:1 or 1:N operation and is not upgradeable.

Modem Rear Panel Connectors Table for L-Band, Rev. A and Later Chassis Versions:

Name

Ref.

Des.

Connector Type

Function

Tx IF Output

J1

BNC Female

70/140 MHz IF Output

Type N Female

L-Band IF Output

Rx IF Input

J3

BNC Female

70/140 MHz IF Input

Type N Female

L-Band IF Input

10/100 Ethernet

J4

RJ-45 Female

Ethernet Management

Async Channel

J6

9-pin D Female

Async Engineering Channel

Ext Ref

J7

BNC Female

External reference input

Alarm

P1

15-pin ‘D’ male

Alarm connector and Form C contacts

RS232/485

P2

9-pin ‘D’ male

Remote Port

AC INPUT

NONE

IEC 320

Prime Power Input

GROUND NONE

10-32

Stud Grounding

Note: This chassis is required for 1:1 or 1:N operation

The European EMC Directive (EN55022, EN50082-1) requires using properly shielded cables for
DATA I/O. These cables are double-shielded from end-to-end, ensuring a continuous ground shield.




5–2