CDM-700 High Speed Satellite Modem

Revision 5

Remote Control

MN/CDM700.IOM

11–9

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Tx Alpha
Rolloff

TAR=

1 byte

Command or Query
Tx Alpha Rolloff, where:
1 = 25%
2 = 35%

Example: TAR=1 (which is a Tx Alpha Rolloff of 25%)

TAR=
TAR?
TAR*
TAR#

TAR?

TAR=x
(see description of
arguments)

Tx Spectrum
Invert

TSI=

1 byte

Command or Query.
Tx Spectrum Invert selection, where:
0=Normal,
1=Tx Spectrum Inverted

Example: TSI=0 (which is normal)

TSI=
TSI?
TSI*
TSI#

TSI? TSI=x

(see description of
arguments)

Tx Scrambler

TSC=

1 byte

Command or Query.
Tx Scrambler state, where:
0=Off
1=On

Example: TSC=1 (Scrambler On)

TSC=
TSC?
TSC*
TSC#

TSC? TSC=x

(see description of
arguments)

Tx Power
Level

TPL=

5 bytes

Command or Query.
Tx Output power level, where:
s=sign ( + / - )
xx.x = Tx Output power level,
L-Band unit: +00.0 and –20.0 dBm.
70/140 MHz unit: +00.0 to –20.0 dBm

Note: Beyond –20 dBm is beyond the specification.

Example: TPL = -13.4

TPL=
TPL?
TPL*
TPL#

TPL?

TPL=sxx.x
(see description of
arguments)

Tx Output
Impendance

IMP=

1 byte

Command or Query.
Tx output impedance, where:
0=50 Ohm
1=75 Ohm

(Valid for 70/140 MHz units only)

Example: IMP=1 (Set impedance to 75 Ohms)

IMP=
IMP?
IMP*
IMP#

IMP? IMP=x

(see description of
arguments)