CDM-700 High Speed Satellite Modem

Revision 5

Remote Control

MN/CDM700.IOM

11–18

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Interface
Alarm Mask

IAM=

7 bytes

Command or Query.
Alarm mask conditions, in form spabcdef, where:
s=slot number
p=port number
a=Tx Cable (0 = masked as Alarm,1 = masked as Fault,2 =Masked)
b=Tx AIS (0 = masked as Alarm,1 = masked as Fault,2 =Masked)
c=Rx AIS (0 = masked as Alarm,1 = masked as Fault,2 =Masked)
d=Bufferslip Alarm (0 = masked as Alarm,1 = masked as Fault,
2 =Masked)
e=External Clock Alarm (0 = masked as Alarm,1 = masked as
Fault,2 =Masked)

(Note: Command valid Only with CDI-10 Dual G.703 interface)

Example: IAM=1101011 ( alarm masks for interface slot 1, port 1 )

IAM=
IAM?
IAM*
IAM#

IAM?sp

IAM=spabcde

HSSI Interface
Alarm Mask

HAM=

7 bytes

Command or Query.
Alarm mask conditions, in form spa, where:
s=slot number
p=port number
21
a=x reserved
b=x reserved
c=x reserved
d=x reserved
e=Ext Clock Alarm (0 = masked as Alarm,1 = masked as Fault,2
=Masked) (Note: Command valid Only with Gigabit Interface)

Example: HAM= 21xxxx0 ( alarm masks for interface slot 2, port 1 )

HAM=
HAM?
HAM*
HAM#

HAM?sp

HAM=spxxxxe