8 data interface (optional), 9 environmental and physical – Comtech EF Data CDM-700 User Manual
Page 150
![background image](https://www.manualsdir.com/files/778751/content/doc150.png)
CDM-700 High Speed Satellite Modem
Revision 5
Summary of Specifications MN/CDM700.IOM
10–8
10.8 Data Interface (Optional)
Note: Additional information about the data interfaces is available in the applicable appendix.
Interface Type
Description
CDI-10
2 independent G.703 interfaces at 75
Ω unbalanced each programmable to
E3/T3/STS-1 34.368/44.736/51.84 Mbps. Line codes are AMI (NONE), HDB3,
and B3ZS.
CDI-50
2 types of OC-3 / STM-1 modules area available and one is selected at the time
of order. Each module has two interfaces: one optical, the other copper (coaxial),
and the user programs the active one
CDI-60
1 each HSSI Port
CDI-70
1 each RJ-45 Port
10.9 Environmental
and
Physical
Temperature
Operating
0 to 50
°C (32 to 122°F)
Storage
-25 to 85
°C (-13 to 185°F)
Humidity
95% maximum, non-condensing
Power Supply Input
AC
100-240 VAC (50 to 60 Hz)
DC
48 VDC
Power Consumption
120 VAC @ 60 Hz
80W, 81.5 VA maximum
220 VAC @ 50 Hz
67W, 87 VA maximum
48 VDC
1.6A, 77W maximum
Dimensions
19W x 18.65D x 1.75H inches
(48W x 47.4D x 4.4D cm)
Weight
15 lbs (7.0 kg) approx
Agency Approvals
EMC
Safety