beautypg.com

Intfc1 hssi: æ cts/rts – Comtech EF Data CDM-700 User Manual

Page 91

background image

CDM-700 High Speed Satellite Modem

Revision 5

Front Panel Operation

MN/CDM700.IOM

6–37

If Intfc1 Rx Clock: Æ Source is selected:

Intfc1 Rx Clock:
Rx-Sat Tx-Terr Internal

This selection determines which source clocks the output of the Rx Buffer for delivering data to
the Rx port at the user interface.

Select Rx-Sat, Tx-Terr or Internal using the

◄ ►

arrow keys. Press

ENTER

. The selections

are as follows:

Selection

Description

Rx-Sat (default)

Effectively disables the Rx Buffer because the input and output
clocks are the same. Normally, the Rx Buffer is set for minimum
when Rx-Sat is selected.

Tx-Terr

Uses the clock from the Tx input (TT) to clock out the Rx Buffer.

Internal

Derives a clock from the internal 10 Mhz reference clock.

If Intfc1 Rx Clock: Æ Invert is selected:

Intfc1 Rx Data Invert:
Normal Inverted (
E)


This feature has been added for compatibility with certain older equipment. Select Normal or
Inverted, using the

◄ ►

arrow keys, to control clock inversion. Press

ENTER

.

If Intfc1 Rx: Æ Enable is selected:

Intfc1 Rx Enable:
Enable Disable (
E)


This selection activates or deactivates the receive (Rx) side of this interface. Disabling the Rx
side deactivates it and changes the data rate to 0.

Select Enable or Disable using the

◄ ►

arrow keys. Press

ENTER

.

Intfc1 HSSI:

Æ CTS/RTS

Intfc1 CTS/RTS:
Normal Fault (
E)


Select Normal or Fault using the

◄ ►

arrow keys. Press

ENTER

.