11–21

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Retrieve next 5
unread Stored
Events

N/A

80 bytes

Query only.
Unit returns the oldest 5 Stored Events which have not yet been
read over the remote control. Reply format: {CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body,
where Sub-body= ABCddmmyyhhmmss,
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Power on/off, or log cleared
C is Fault Code numbers, as in FLT? or Info Code, which is:

00=Power Off
01=Power On
02=Log Cleared
03=Global Config Change
04=Redundancy Config Change

If there are less than 5 events to be retrieved, the remaining
positions are padded with zeros.
If there are no new events, the response is RNE*.

N/A

RNE?

RNE={CR}ABCCddmmy
yhhmmss{CR}ABCCddm
myyhhmmss{CR}ABCCd
dmmyyhhmmss{CR}AB
CCddmmyyhhmmss
{CR}ABCCddmmyyhhm
mss

Clear All
Stored Events

CAE=

None

Command only.
Forces the software to clear the software events log.

Note: This command takes no arguments

Example: CAE=

CAE=
CAE?
CAE*
CAE#

N/A

N/A

Initialize
Events Pointer

IEP=

None

Command only.
Resets internal pointer to allow RNE? queries to start at the
beginning of the stored events log.

IEP=
IEP#

N/A

N/A

Rx Eb/No

N/A

4 bytes

Query only.
Unit returns the value of Eb/No, between 0 and 16 dB,
resolution 0.1 dB.
Returns 99.9 if demod is unlocked.

Example EBN=12.3 (which is Eb/No = 12.3 dB)
For values greater than 16.0 dB, the reply will be: EBN=+016

N/A

EBN?

EBN=xxxx