Comtech EF Data CDM-700 User Manual
Page 171
![background image](https://www.manualsdir.com/files/778751/content/doc171.png)
CDM-700 High Speed Satellite Modem
Revision 5
Remote Control
MN/CDM700.IOM
11–21
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Retrieve next 5
unread Stored
Events
N/A
80 bytes
Query only.
Unit returns the oldest 5 Stored Events which have not yet been
read over the remote control. Reply format: {CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body,
where Sub-body= ABCddmmyyhhmmss,
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Power on/off, or log cleared
C is Fault Code numbers, as in FLT? or Info Code, which is:
00=Power Off
01=Power On
02=Log Cleared
03=Global Config Change
04=Redundancy Config Change
If there are less than 5 events to be retrieved, the remaining
positions are padded with zeros.
If there are no new events, the response is RNE*.
N/A
RNE?
RNE={CR}ABCCddmmy
yhhmmss{CR}ABCCddm
myyhhmmss{CR}ABCCd
dmmyyhhmmss{CR}AB
CCddmmyyhhmmss
{CR}ABCCddmmyyhhm
mss
Clear All
Stored Events
CAE=
None
Command only.
Forces the software to clear the software events log.
Note: This command takes no arguments
Example: CAE=
CAE=
CAE?
CAE*
CAE#
N/A
N/A
Initialize
Events Pointer
IEP=
None
Command only.
Resets internal pointer to allow RNE? queries to start at the
beginning of the stored events log.
IEP=
IEP#
N/A
N/A
Rx Eb/No
N/A
4 bytes
Query only.
Unit returns the value of Eb/No, between 0 and 16 dB,
resolution 0.1 dB.
Returns 99.9 if demod is unlocked.
Example EBN=12.3 (which is Eb/No = 12.3 dB)
For values greater than 16.0 dB, the reply will be: EBN=+016
N/A
EBN?
EBN=xxxx